# Uniform Grid
Specification for a uniform EME grid: the simulation domain is evenly divided into cells along the propagation axis, and all cells share the same mode specification. This is the simplest option and is suitable when the cross-section varies smoothly along the propagation direction.
# Number of Cells
num_cells: Number of cells in the uniform EME grid.
Type: integer
- Unit: unitless
- Constraint: greater than 0
- Default: 5
# Mode Specification
mode_spec: Mode specification used by all cells of the uniform grid.
← Ports Explicit Grid →