# Surface Field Time Monitor
A Surface Field Time Monitor records electromagnetic fields in the time domain on perfect electric conductor (PEC) and non-penetrable lossy-metal surfaces inside a three-dimensional monitor region. Selecting E records the electric field normal to each surface, while selecting H records the magnetic field tangential to each surface. Use this monitor to analyze the time dependence of surface fields or create animations of field-pattern evolution.
This object corresponds to tidy3d.SurfaceFieldTimeMonitor (opens new window).
The monitor region must have a nonzero size along all three axes.
WARNING
Surface monitors are currently a beta feature. Verify surface monitor results carefully.
# Name
name: Unique name for the monitor.
- Required field
# Geometry
Specification of the three-dimensional monitor region.
# Center+Size
Object definition through a center position and size.
center: Center of the monitor in x, y, and z-directions.
- Type: floating-point number
- Unit: m, mm (default unit), um
size: Size of the monitor in x, y, and z-directions.
- Type: floating-point number
- Unit: m, mm (default unit), um
- Constraint: greater than 0 along every axis
- Required field
# Bounds
Object definition through minimum and maximum coordinate bounds.
min: Values of the x, y, and z coordinates defining the lower corner of the monitor.
- Type: floating-point number
- Unit: m, mm (default unit), um
- Required field
max: Values of the x, y, and z coordinates defining the upper corner of the monitor.
- Type: floating-point number
- Unit: m, mm (default unit), um
- Required field
NOTE
Surface monitors require a 3D volume. The minimum and maximum bounds must differ along every axis; 1D and 2D regions are not supported.
# Settings
# Fields
fields: Surface field groups stored by the monitor.
- Options:
- E: Electric field normal to each supported metal surface.
- H: Magnetic field tangential to each supported metal surface.
- Default: E and H
- Constraint: select at least one field group
NOTE
Selecting only E records the normal electric field, but derived surface current density Js is unavailable. Selecting only H records the tangential magnetic field and supports derived Js. Poynting-vector data requires both E and H. Selecting neither E nor H is invalid.
# Time
start: Time at which to start monitor recording.
- Type: non-negative floating-point number
- Unit: s, ms, us, ns (default unit), ps, fs
- Default: 0
stop: Time at which to stop monitor recording. If no value is specified, recording continues until the end of the simulation.
- Type: non-negative floating-point number
- Unit: s, ms, us, ns (default unit), ps, fs
- Default: end of simulation
interval: Number of simulation time steps between recorded samples. Set the interval to 1 for the highest available time resolution; higher values downsample the data and reduce the number of recorded samples.
- Type: positive integer
- Default: 1
NOTE
Recording surface fields at every time step and grid point can produce a large dataset. Increase interval when full time resolution is not required.
# Advanced
colocate: Colocate the recorded fields on each supported metal surface. This setting is labeled Colocate fields in the GUI.
- Type: boolean
- Default: True
- Constraint: fixed to True for surface monitors
use_colocated_integration: Use colocated fields for flux, dot-product, and overlap integrations. This setting is labeled Use colocated integration in the GUI.
- Type: boolean
- Default: True
- Constraint: fixed to True for surface monitors
interval_space: Number of grid-step intervals between recorded points in the x, y, and z-directions. This setting is labeled Subsample spatial grid in the GUI.
- Type: three positive integers
- Default: (1, 1, 1)
- Constraint: fixed to (1, 1, 1); spatial downsampling is not currently supported