# Optical Perturbation

Set it to True to specify material perturbation due to thermal effects as a linear function of temperature monitor data.

  • Default: False

# Medium Perturbation

Optical perturbation specifications to Medium.

# Thermo-optic coefficients

Permittivity thermo-optic coefficient: Sensitivity (derivative) of the material permittivity with respect to temperature.

Type: floating-point number

  • Unit: 1/K (default) or 1/C

Conductivity thermo-optic coefficient: Sensitivity (derivative) of the material optical conductivity with respect to temperature.

Type: floating-point number

  • Unit: 1/K (default) or 1/C

# Reference temperature

temperature_ref: Temperature at which the perturbation is zero.

Type: floating-point number

  • Unit: K (default) or C

# Temperature range

temperature_range: Temperature range in which the perturbation model is valid.

Type: floating-point number

  • Unit: K (default) or C

# PoleResidue Perturbation

Optical perturbation specifications to the PoleResidue model.

# Thermo-optic coefficients

Eps_inf thermo-optic coefficient: Sensitivity (derivative) of the PoleResidue model infinity epsilon with respect to temperature.

Type: floating-point number

  • Unit: 1/K (default) or 1/C

Poles thermo-optic coefficient: Sensitivity (derivative) of the real and imaginary parts of the PodeResidue model poles with respect to temperature.

Type: floating-point number

  • Unit: 1/K (default) or 1/C

# Reference temperature

temperature_ref: Temperature at which the perturbation is zero.

Type: floating-point number

  • Unit: K (default) or C

# Temperature range

temperature_range: Temperature range in which the perturbation model is valid.

Type: floating-point number

  • Unit: K (default) or C